What are the precautions to be taken before installing the blue PC solar panel?
1. It is necessary to check whether the expansion reserve of the anti blue PC sun board is reasonable, whether the cutting size of the board is qualified, and whether the reserved expansion gap is uniform and sufficient.
2. When installing and fixing the blue PC solar panel with accessories, it is best to tear off the protective film by 30mm to 50mm to avoid the accessory pressure strip from pressing the protective film.
3. The blue PC solar panel has a UV coating. When installing, be sure to distinguish between the UV resistant side facing outward and the side without the UV coating facing inward. Do not install it incorrectly.
4. If it is a hollow solar panel installation project, at least 20mm of space should be maintained at the edges of the panel connections, and the clamping accessories connected to the solar panel installation project should have at least one less rib.
5. After installing the accessories, when compacting the sealing strip and board, tighten the self sealing nails required for the connection evenly without excessive force. If leakage occurs due to installation errors, it should be treated with sealing glue in a timely manner.
6. If you need to drill and nail the board yourself, you must consider the thermal expansion and contraction performance and principle of PC board, and leave reasonable gaps.
7. Check if there is any leakage after the board installation is completed, and check all aspects that need attention, including appearance, quality, and so on.